Starting of an engine from "stop" state is something which needs to be done with care, especially if the interval of starting is sufficiently long. The following is a checklist of all the checks which ideally need to be carried out before starting the generator. In actual practice sometimes the engineers might take some of these for granted and skip, but it is advisable not to indulge in such a practice. Infact these checks are generic for any four stroke engine starting process
Check the turbocharger sump oil level, governor, alternator, forward and aft lube oil levels, and diesel oil level in service tank
Open the indicator cock
Prime the lube oil to all parts by hand pump or by motor driven priming pump
Ensure that all jacket cooler valves, lube oil cooler valves, air cooler valves should be in open position
With use of the Turning bar turn the fly wheel and check for any resistance on the bottom end bearing and check any water / fuel coming out through indicator cocks
While turning engine, check all visible lube oil points are lubricated
Remove the turning bar from fly wheel and put in the place
Drain the auxiliary air bottle
Blow through engine (ie: by turning engine with air). In order to ensure that no water is inside combustion chamber if it is present it may cause water hammering
Close the indicator cocks and pull lever from stop to start
When the needle in RPM indicator deflects to some value of (0-25 rpm) put the lever in run condition
The engine will run on fuel oil once the generator picks up the rated speed
Put generator on load by closing air circuit breaker
For checking the alternator fore and aft bearing lube oil level by opening oil plug in the alternator and the ring bearing while rotating splash lube oil from the sump can be seen
In order to synchronize the incoming generator with running generator syncroscope method/dark lamp method is used